Isolation and concentration
Purge and trap
Purge and trap is a powerful procedure for extracting and concentrating volatile organic compounds from soil, sediment, water, food, beverages, etc. It is especially useful for poorly water-soluble compounds and those with boiling points above 200C. The procedure involves bubbling an inert gas (nitrogen or helium) through an aqueous sample or suspension at ambient temperature, which causes volatile organic compounds to be transferred into the vapour phase. Alternatively, an inert gas is passed across the headspace of the sample and onto the trap. The removal of volatile components from the headspace causes the sample–headspace equilibrium to be perturbed such that further vaporisation of the volatile components occurs, resulting in concentration of sample in the trap. During the purge step, purge gas sweeps the vapour through a trap containing adsorbent materials that retain the volatilised compounds. Water vapour may be removed by dry purging. The trap is rapidly heated to 5–10C below the desorption tempera ture. The valve is then switched to join the trap flow to the carrier-gas flow, and the trap heated to its desorption temperature for a fixed time. Adsorbent tubes are usually packed with multiple beds of sorbent materials, each one more active than the preceding one, which allows compounds with a wide range of boiling points and polarities to be analysed simultaneously. During purge, the smaller and more nonpolar solutes are readily carried down the beds, and since the carrier gas passes in the opposite direction during the desorption phase, the larger and more polar compounds do not come into contact with the innermost active beds, from which their release may be difficult to effect.
0
0
الاكثر قراءة في تحليل السموم
اخر الاخبار
اخبار العتبة العباسية المقدسة